2 PRODUCT DESCRIPTION
Table 2–2: OTHER DEVICE FUNCTIONS
FUNCTION
Breaker control
Breaker flashover
Contact inputs (up to 96)
Contact outputs (up to 64)
Control pushbuttons
Digital counters (8)
Digital elements (48)
Direct inputs and outputs (32)
Disconnect switches (24)
DNP 3.0 or IEC 60870-5-104 protocol
Ethernet Global Data protocol (optional)
a) OVERVIEW
The B30 is available as a 19-inch rack horizontal mount or reduced-size (¾) vertical unit and consists of the following mod-
ules: power supply, CPU, CT/VT, digital input and output, transducer input and output, and inter-relay communications.
Each of these modules can be supplied in a number of configurations specified at the time of ordering. The information
required to completely specify the relay is provided in the following tables (see chapter 3 for full details of relay modules).
Order codes are subject to change without notice. See the web page for the product for the latest ordering options.
NOTE
The order code structure is dependent on the mounting option (horizontal or vertical) and the type of CT/VT modules (regu-
lar CT/VT modules or the HardFiber modules). The order code options are described in the following sub-sections.
b) ORDER CODES WITH TRADITIONAL CTS AND VTS
The order codes for the horizontal mount units with traditional CTs and VTs are shown below.
Table 2–3: B30 ORDER CODES FOR HORIZONTAL UNITS
B30
-
*
**
- *
*
* - F
BASE UNIT
B30
|
|
|
|
|
CPU
E
|
|
|
|
J
|
|
|
|
K
|
|
|
|
N
|
|
|
|
S
|
|
|
|
GE Multilin
FUNCTION
Event recorder
FlexElements™ (8)
FlexLogic™ equations
IEC 61850 communications (optional)
Metering: current, voltage, frequency
Modbus communications
Modbus user map
Non-volatile latches
Non-volatile selector switch
Oscillography
Selector switch
**
- H
**
- L
**
- N
**
- S
**
- U
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
B30 Bus Differential System
FUNCTION
Setting groups (6)
Teleprotection inputs and outputs
Time synchronization over SNTP
Transducer inputs and outputs
User-definable displays
User-programmable fault reports
User-programmable LEDs
User-programmable pushbuttons
User-programmable self-tests
Virtual inputs (64)
Virtual outputs (96)
**
- W/X
**
Full Size Horizontal Mount
|
|
Base Unit
|
|
RS485 and RS485
|
|
RS485, multi-mode ST 100Base-FX, and 10/100Base-T
|
|
RS485, multi-mode ST redundant 100Base-FX, and 10/100Base-T
|
|
RS485 and 10/100Base-T
|
|
RS485 and six-port managed Ethernet switch (four 100Base-FX and two 100Base-T)
2.1 INTRODUCTION