GE B30 Instruction Manual page 415

Bus differential system, ur series
Hide thumbs Also See for B30:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 14 of 52)
ADDR
REGISTER NAME
4087
Port 1 IP Address
4089
Port 1 IP Subnet Mask
408B
Port 1 Gateway IP Address
408D
Network Address NSAP
409A
DNP Channel 1 Port
409B
DNP Channel 2 Port
409C
DNP Address
409E
DNP Client Addresses (2 items)
40A3
TCP Port Number for the Modbus protocol
40A4
TCP/UDP Port Number for the DNP Protocol
40A5
TCP Port Number for the HTTP (Web Server) Protocol
40A6
Main UDP Port Number for the TFTP Protocol
40A7
Data Transfer UDP Port Numbers for the TFTP Protocol
(zero means "automatic") (2 items)
40A9
DNP Unsolicited Responses Function
40AA
DNP Unsolicited Responses Timeout
40AB
DNP Unsolicited Responses Maximum Retries
40AC
DNP Unsolicited Responses Destination Address
40AD
Ethernet Operation Mode
40AE
DNP Current Scale Factor
40AF
DNP Voltage Scale Factor
40B0
DNP Power Scale Factor
40B1
DNP Energy Scale Factor
40B2
DNP Power Factor Scale Factor
40B3
DNP Other Scale Factor
40B4
DNP Current Default Deadband
40B6
DNP Voltage Default Deadband
40B8
DNP Power Default Deadband
40BA
DNP Energy Default Deadband
40BC
DNP Power Factor Default Deadband
40CE
DNP Other Default Deadband
40C0
DNP IIN Time Synchronization Bit Period
40C1
DNP Message Fragment Size
40C2
DNP Client Address 3
40C4
DNP Client Address 4
40C6
DNP Client Address 5
40C8
DNP Number of Paired Binary Output Control Points
40C9
DNP TCP Connection Timeout
40CA
Reserved (22 items)
40E0
TCP Port Number for the IEC 60870-5-104 Protocol
40E1
IEC 60870-5-104 Protocol Function
40E2
IEC 60870-5-104 Protocol Common Address of ASDU
40E3
IEC 60870-5-104 Protocol Cyclic Data Transmit Period
40E4
IEC 60870-5-104 Current Default Threshold
40E6
IEC 60870-5-104 Voltage Default Threshold
40E8
IEC 60870-5-104 Power Default Threshold
40EA
IEC 60870-5-104 Energy Default Threshold
40EC
IEC 60870-5-104 Power Default Threshold
40EE
IEC 60870-5-104 Other Default Threshold
40F0
IEC 60870-5-104 Client Address (5 items)
4104
IEC 60870-5-104 Redundancy Port Enabled/Disabled
4105
Reserved (57 items)
413E
High Enet Traffic Function
413F
High Enet Traffic Events
GE Multilin
RANGE
0 to 4294967295
0 to 4294967295
0 to 4294967295
---
0 to 5
0 to 5
0 to 65519
0 to 4294967295
1 to 65535
1 to 65535
1 to 65535
1 to 65535
0 to 65535
0 to 1
0 to 60
1 to 255
0 to 65519
0 to 1
0 to 8
0 to 8
0 to 8
0 to 8
0 to 8
0 to 8
0 to 100000000
0 to 100000000
0 to 100000000
0 to 100000000
0 to 100000000
0 to 100000000
1 to 10080
30 to 2048
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 32
10 to 7200
0 to 1
1 to 65535
0 to 1
0 to 65535
1 to 65535
0 to 100000000
0 to 100000000
0 to 100000000
0 to 100000000
0 to 100000000
0 to 100000000
0 to 4294967295
0 to 1
0 to 1
0 to 1
0 to 1
B30 Bus Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F003
---
1
F003
---
1
F003
---
---
F074
---
1
F177
---
1
F177
---
1
F001
---
1
F003
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F102
s
1
F001
---
1
F001
---
1
F001
---
1
F192
---
1
F194
---
1
F194
---
1
F194
---
1
F194
---
1
F194
---
1
F194
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
min
1
F001
---
1
F001
---
1
F003
---
1
F003
---
1
F003
---
1
F001
s
1
F001
---
1
F001
---
1
F001
---
1
F102
---
1
F001
s
1
F001
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F126
---
1
F001
---
1
F102
---
1
F102
DEFAULT
56554706
4294966272
56554497
0
0 (None)
B
0 (None)
1
0
502
20000
80
69
0
0 (Disabled)
5
10
1
1 (Full-Duplex)
2 (1)
2 (1)
2 (1)
2 (1)
2 (1)
2 (1)
30000
30000
30000
30000
30000
30000
1440
240
0
0
0
0
120
0
2404
0 (Disabled)
0
60
30000
30000
30000
30000
30000
30000
0
0 (No)
0
1 (Enabled)
0 (Disabled)
B-21

Advertisement

Table of Contents
loading

Table of Contents