Emerson Rosemount 5408 Reference Manual page 187

Level transmitters. non-contacting radar
Hide thumbs Also See for Rosemount 5408:
Table of Contents

Advertisement

Reference Manual
00809-0100-4408, Rev BA
7. Using the box provided on the nameplate, the User shall
permanently mark the type of protection chosen for the
specific installation. Once the type of protection has been
marked it shall not be changed.
8. Display glass shall be positioned in such a way as to minimize
the risk of mechanical impact.
9. The applicable temperature class, ambient temperature
range and process temperature range of the equipment is as
follows;
Temperature class /
Ambient
Maximum surface
temperature
temperature
range
Gas & Dust groups:
-60°C ≤ Ta ≤ 70°C
T2 / T250°C
-60°C ≤ Ta ≤ 70°C
T3 / T200°C
-60°C ≤ Ta ≤ 70°C
T4 / T135°C
-60°C ≤ Ta ≤ 70°C
T5 / T100°C
-60°C ≤ Ta ≤ 70°C
T6 / T85°C
I1
ATEX Intrinsic Safety
Certificate: FM15ATEX0055X
Standards: EN 60079-0:2012, EN 60079-11:2012, EN
60079-26:2015
Markings:
II 1G Ex ia IIC T4...T2 Ga
II 1/2G Ex ib IIC T4...T2 Ga/Gb
II 1D Ex ia IIIC T85°C...T250°C Da
II 2D Ex ib IIIC T85°C...T250°C Db
(-60°C ≤ Ta ≤ +70°C)
Safety parameter
Voltage U
i
Current I
i
Power P
i
Capacitance C
i
Inductance L
i
Specific Conditions of Use (X):
1. The Model 5408 Level Transmitter will not pass the 500Vrms
dielectric strength test between the circuits and the earth
ground. This must be taken into account during installation.
2. Plastic wire-on tag, Plastic part of Process Seal Antenna and
Non-standard paint options (paint options other than
Rosemount Blue) may cause risk from Electrostatic
discharge. Avoid installation that could cause electrostatic
build-up, and only clean with a damp cloth.
3. Appropriate cable, glands, and plugs need to be suitable for a
temperature of 5°C greater than the maximum specified
ambient temperature for location where installed.
Product Certifications
Process
temperature
range
-60°C to 250°C
-60°C to 195°C
-60°C to 130°C
-60°C to 95°C
-60°C to 80°C
HART
30 V
133 mA
1.0 W
7.3 nF
0
4. The Transmitter can be installed in the boundary wall
between a Category 1 and Category 2 location. In this
configuration, the process connection is installed in
Category 1, while the transmitter housing is installed in
Category 2. Refer to Control Drawing D7000002-885.
5. Using the box provided on the nameplate, the User shall
permanently mark the type of protection chosen for the
specific installation. Once the type of protection has been
marked it shall not be changed.
6. The applicable temperature class, ambient temperature
range and process temperature range of the equipment is as
follows;
Temperature class /
Ambient
Maximum surface
temperature
temperature
range
Gas groups:
-60°C ≤ Ta ≤ 70°C
T2
-60°C ≤ Ta ≤ 70°C
T3
-60°C ≤ Ta ≤ 70°C
T4
Dust groups:
-60°C ≤ Ta ≤ 70°C
T250°C
-60°C ≤ Ta ≤ 70°C
T200°C
-60°C ≤ Ta ≤ 70°C
T135°C
-60°C ≤ Ta ≤ 70°C
T100°C
-60°C ≤ Ta ≤ 70°C
T85°C
N1 ATEX Type N: Non-Sparking
Certificate: FM15ATEX0056X
Standards: EN 60079-0:2012, EN 60079-15:2010
Markings:
II 3G Ex nA IIC T4...T2 Gc, IP65
(-34°C ≤ Ta ≤ +70°C)
V ≤ 42.4V, I ≤ 23 mA
Specific Conditions of Use (X):
1. The Model 5408 Level Transmitter will not pass the 500Vrms
dielectric strength test between the circuits and the earth
ground. This must be taken into account during installation.
2. Plastic part of Process Seal Antenna may cause risk from
Electrostatic discharge. Avoid installation that could cause
electrostatic build-up, and only clean with a damp cloth.
3. Cable entries must be used which maintain the ingress
protection of the enclosure to at least IP65. To maintain the
ingress protection ratings, Covers and Sensor Module to be
fully tightened and PTFE tape or pipe dope is required for
cable entries and blanking plugs. See Instruction Manual on
application requirements.
4. The applicable temperature class, ambient temperature
range and process temperature range of the equipment is as
follows;
Product Certifications
November 2017
Process
temperature
range
-60°C to 250°C
-60°C to 195°C
-60°C to 130°C
-60°C to 250°C
-60°C to 195°C
-60°C to 130°C
-60°C to 95°C
-60°C to 80°C
175

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sis

Table of Contents