Emerson Rosemount 5408 Reference Manual page 160

Level transmitters. non-contacting radar
Hide thumbs Also See for Rosemount 5408:
Table of Contents

Advertisement

Specifications and Reference Data
November 2017
Table A-8. Rosemount 5408 Level Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to
additional delivery lead time.
Welding procedure qualification record documentation
Q66
Welding Procedure Qualification Record (WPQR)
Q67
Welder Performance Qualification (WPQ)
Q68
Welding Procedure Specification (WPS)
Q79
WPQR/WPQ/WPS
Dye penetration test certificate
Q73
Certificate of Liquid Penetrant Inspection
Positive material identification certificate
Q76
Positive Material Identification Certificate of Conformance
Extended product warranty
WR3
3-year Limited Warranty
WR5
5-year Limited Warranty
Conduit electrical connector (shipped uninstalled)
EC
M 12, 4-pin, Male connector (eurofast)
MC
A size Mini, 4-pin, Male connector (minifast)
Specials (see
page
142)
PXXXX
Custom Engineered Solutions beyond standard model codes. Consult factory for details.
Typical model number: 5408 A 1 S H A 1 E5 1 R 3 AB CAB 3 M5 DA1
1.
G½ thread form is not available with hazardous locations approvals.
2.
Type A flat face for EN 1092-1 flanges.
3.
Type B1 raised face for EN 1092-1 flanges.
4.
Only available with cone antenna.
5.
Only available with process seal antenna.
6.
Pressure limit is derated for process temperatures above 100 °F (38 °C), see
7.
Refer to
Figure A-6 on page 140
8.
Option code PC1 is for cone antennas only, and requires matching flange and antenna sizes. Note that all parabolic antennas come with an integrated air purge connection.
9.
Only available with parabolic antenna and 4-in. (DN100) cone antenna.
10.
The standard alarm setting is high.
11.
Only applies to flanged process connections with welded construction; only applicable to cone antennas (see
12.
Hydrostatic testing is only available for cone antennas and process seal antennas with flanged process connections.
13.
Certificate includes all pressure retaining and wetted parts.
14.
Not available with parabolic antenna.
15.
Requires ½-14 NPT conduit/cable threads (code 1). Available with Intrinsically Safe approvals only.
148
(11)
for pressure/temperature ratings of Tri Clamp connection.
(11)
(15)
Figure A-4 on page 140
for details.
Reference Manual
00809-0100-4408, Rev BA
Table A-10 on page
154).
Specifications and Reference Data

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sis

Table of Contents