A.2.10System Integration; Physical Specifications; Material Selection; Engineered Solutions - Emerson Rosemount 5408 Reference Manual

Level transmitters. non-contacting radar
Hide thumbs Also See for Rosemount 5408:
Table of Contents

Advertisement

Specifications and Reference Data
November 2017
An air purge connection is also available for cone antennas
with flanged connection by selecting option code PC1. This
option consists of an antenna with purge holes and a
separate air purge ring (see
Figure A-9. Air Purging
Incoming air supply specification
Maximum pressure: 190 psi (13 bar)
Recommended pressure: 100 to 115 psi (7 to 8 bar)
Inlet/outlet connection: BSPP (G)
Air consumption: 252 gal/min at 65 psi (955 l/min at 4.5
bar)
A.2.10 System integration
Rosemount 333 HART Tri-Loop
By sending the digital HART signal to the
optional HART Tri-Loop, it is possible to have up
to three additional 4–20 mA analog signals.
See the Rosemount 333 HART Tri-Loop
Data Sheet
for additional information.
Emerson
Wireless 775 THUM
The optional Emerson Wireless 775
THUM Adapter can be mounted directly
on the transmitter or by using a remote
mounting kit.
IEC 62591 (WirelessHART
data and diagnostics, and adds wireless to almost any
measurement point.
142
Figure
A-9).
/
-in.
3
8
Adapter
®
) enables access to multivariable
See the Emerson Wireless 775 THUM Adapter
Sheet
and
Technical Note
A.3 Physical specifications
A.3.1 Material selection
Emerson provides a variety of Rosemount products with
various product options and configurations including
materials of construction that can be expected to perform
well in a wide range of applications. The Rosemount
product information presented is intended as a guide for the
purchaser to make an appropriate selection for the
application. It is the purchaser's sole responsibility to make
a careful analysis of all process parameters (such as all
chemical components, temperature, pressure, flow rate,
abrasives, contaminants, etc.), when specifying product,
materials, options, and components for the particular
application. Emerson is not in a position to evaluate or
guarantee the compatibility of the process fluid or other
process parameters with the product, options,
configuration, or materials of construction selected.
A.3.2 Engineered solutions
When standard model codes are not sufficient to fulfill
requirements, please consult the factory to explore possible
Engineered Solutions. This is typically, but not exclusively,
related to the choice of wetted materials or the design of a
process connection. These Engineered Solutions are part of
the expanded offerings and may be subject to additional
delivery lead time. For ordering, factory will supply a special
P-labeled numeric option code that should be added at the
end of the standard model string.
Product
A.3.3 Housing and enclosure
Electrical connections
Two cable/conduit entries (½-14 NPT, M20 x 1.5, or G½)
Optional adapters: M12 4-pin male eurofast
size Mini 4-pin male minifast
Reference Manual
00809-0100-4408, Rev BA
Product Data
for additional information.
®
connector or A
®
connector
Specifications and Reference Data

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sis

Table of Contents