Figure 3-2. Recommended Mounting Position
L
3.3.2

Free space requirements

If the transmitter is mounted close to a wall or other tank obstructions such as heating coils and ladders,
noise might appear in the measurement signal. Therefore the following minimum clearance, according
to
Table
For easy access to the transmitter, mount it with sufficient service space (see
Figure 3-3. Free Space Requirements
Table 3-1. Distance to Tank Wall (L)
Application
Liquids
Solids
Mechanical Installation
3-1, must be maintained.
A
B
L
Minimum
8 in. (200 mm)
8 in. (200 mm)
Mechanical Installation
November 2017
Table
3-2).
Recommended
/
of tank radius
1
2
2
/
of tank radius
3