5. Check:
• Resistance
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
TIP
The resistance values shown were obtained at
the standard measuring temperature of 20 C
(68 F). If the measuring temperature is not 20
C (68 F), the specified measuring conditions
will be shown.
Intake air temperature sensor re-
sistance
5.40–6.60 k at 0 C (32 F)
290–390  at 80 C (176 F)