Loading Software Updates
4.1 Loading the Software
manually from the ACA
You can connect the ACA 21-USB to a USB port of your PC like a
conventional USB stick and copy the device software into the main directory
of the ACA 12-USB.
Connect the ACA 21-USB onto which you copied the device software with
the USB port of the device.
Open the system monitor
Select 2 and press the Enter key to copy the software from the ACA 21-
USB into the local memory of the device. At the end of the update, the
system monitor asks you to press any key to continue.
Select 3 to start the new software on the device.
The system monitor offers you additional options in connection with the
software on your device:
selecting the software to be loaded
starting the software
performing a cold start
Basic Configuration
Release 6.0 07/2010
4.1 Loading the Software manually
(see page 16 "Opening the system
from the ACA
monitor").