Operation Diagnosis
Note: With a non-redundant voltage supply, the device reports the absence
of a supply voltage. If you do not want this message to be displayed, feed the
supply voltage over both inputs or switch off the monitoring
"Monitoring the Device Status via the Signal
9.2.1
Configuring the Device Status
Select the Diagnostics:Device Status dialog.
In the "Monitoring" field, you select the events you want to monitor.
To monitor the temperature, you set the temperature thresholds in
the Basics:System dialog at the end of the system data.
enable
configure
device-status monitor all
error
device-status trap enable
Note: The above CLI commands activate the monitoring and the trapping
respectively for all the supported components. If you want to activate or
deactivate monitoring only for individual components, you will find the
corresponding syntax in the CLI manual or in the help (Input ?) of the CLI
console.
182
9.2 Monitoring the Device Status
Contact").
Switch to the Privileged EXEC mode.
Switch to the Configuration mode.
Include all the possible events in the device
status determination.
Enable a trap to be sent if the device status
changes.
(see on page 185