Loading/saving settings
3.1.1
Loading from the local non-volatile memory
When loading the configuration data locally, the device loads the
configuration data from the local non-volatile memory if no ACA is connected
to the device.
Select the
Basics: Load/Save dialog.
In the "Load" frame, click "from Device".
Click "Restore".
enable
copy nvram:startup-config
system:running-config
3.1.2
Loading from the AutoConfiguration Adapter
If a ACA is connected to the device, the device automatically loads its
configuration from the ACA during the boot procedure.
The chapter
"Saving locally (and on the ACA)"
save a configuration file on an ACA.
Note: The device allows you to trigger the following events when the
configuration stored on the ACA does not match that in the device:
an alarm (trap) is sent
the device status is updated
Status"),
the status of the signal contacts is updated
the Signal
Contact").
Basic Configuration
Release 6.0 07/2010
Switch to the Privileged EXEC mode.
The device loads the configuration data from the
local non-volatile memory.
(see on page 179 "Configuring
(see on page 181 "Monitoring the Device
3.1 Loading settings
on
page 59
describes how to
Traps"),
(see on page 185 "Controlling