Synchronizing the System Time in the
Network
Select the Time:SNTP dialog.
Activate SNTP globally in the "Operation" frame.
Activate the SNTP client (client status) in the "Configuration SNTP
Client" frame.
In the "Configuration SNTP Client" frame, enter:
– "External server address": 10.0.1.2
– "Request interval": 30
– "Accept SNTP Broadcasts": No
Activate the SNTP server (server status) in the "Configuration SNTP
Server" frame.
In the "Configuration SNTP Server" frame, enter:
– "Anycast destination address": 0.0.0.0
– "VLAN ID": 1
Click "Set" to temporarily save the entry in the configuration.
enable
configure
sntp operation on
sntp operation client on
sntp client server primary
10.0.1.2
sntp client request-interval
30
sntp client accept-broadcast
off
sntp operation server on
sntp anycast address 0.0.0.0 Enter the SNTP server Anycast destination
sntp anycast vlan 1
Enter the global PTP parameters.
Select the Time:PTP:Global dialog.
Activate the function in the "Operation IEEE 1588 / PTP" frame.
Select v1-boundary-clock for "PTP version mode".
Click "Set" to temporarily save the entry in the configuration.
114
7.3 Precision Time Protocol
Switch to the Privileged EXEC mode.
Switch to the Configuration mode.
Switch on SNTP globally.
Switch on SNTP client.
Enter the IP address of the external SNTP server
10.0.1.2.
Enter the value 30 seconds for the SNTP server
request interval.
Deactivate "Accept SNTP Broadcasts".
Switch on SNTP server.
address 0.0.0.0.
Enter the SNTP server VLAN ID 1.
Basic Configuration
Release 6.0 07/2010

Hide quick links: