3

Technical data

General data

Dimensions
OCTOPUS 8M...
W x H x D
OCTOPUS 16M...
OCTOPUS 24M...
Weight
OCTOPUS 8M
OCTOPUS 8M Train
OCTOPUS 8M-8PoE
OCTOPUS 8M-6PoE
OCTOPUS 16M
OCTOPUS 16M Train
OCTOPUS 16M-8PoE
OCTOPUS 16M-2FX
OCTOPUS 16M-8PoE-2FX
OCTOPUS 24M
OCTOPUS 24M Train
OCTOPUS 24M-2FX
Voltage supply
Operating voltage
OCTOPUS ... (without PoE)
OCTOPUS ...PoE...
Overload current
protection at input
Isolating voltage
OCTOPUS ... (without PoE or Train)
between operating
voltage connec-
tors and housing
OCTOPUS ... Train
OCTOPUS ...PoE...
Signal contact
Surrounding
Storage temperature
Humidity
Atmospheric pressure
Operating
OCTOPUS...
temperature
Protection types
Protection type
26
189 mm x 184 mm x 70 mm
189 mm x 261 mm x 70 mm
189 mm x 338 mm x 70 mm
1310 g
1310 g
1310 g
1310 g
1920 g
1920 g
1920 g
1950 g
1950 g
2540 g
2540 g
2570 g
safety extra-low voltage (SELV/
PELV), redundant inputs decou-
pled.
Relevant for North America: Nec
Class 2 power source 5 A maxi-
mum.
9.6 to 60 V DC
46 to 58 V DC
non-changeable fuse
800 V DC
The isolating voltage is limited to
90 V DC (1 mA) by protective com-
ponents.
707 V DC
2.250 V DC
1 A max.,
60 V DC max. or 30 V AC max.
Surrounding air: -40 °C to +85 °C,
-40 °F to +185 °F
0% to 95% (non condensing)
up to 2.000 m (795 hPa), higher
altitudes on demand
Surrounding air -40 °C to +70 °C,
-40 °F to +158 °F
IP 67
OCTOPUS 8M/16M/24M
Release
07/2008

Hide quick links: