Emv And Stability; Network Size - Hirschmann RS20 User Manual

Industrial
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

EMV and stability

EMV interference
proof
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-9
EMV emitted immunity
EN 55022
FCC 47 CFR Part 15
Germanischer Lloyd
Stability
Vibration
Shock

Network size

Length of a twisted pair segment
100 m approx.
Table 1: TP port 10BASE-T / 100BASE-TX
Connec-
Wave
tor
length
MicroFX MM 1300 nm 50/125 µm
MircoFX MM 1300 nm 62.5/125 µm 0-11 dB
Table 2: F/O port 100BASE-FX
OCTOPUS 8M/16M/24M
Release
07/2008
Discharge of static electricity
Contact discharge
Air discharge
Electromagnetic fields
Test level 3 (80 - 2000 MHz)
Fast transients (burst)
- Power line
- Data line
Surge voltage
- Power line, line/line
- Power line, line/earth
- Data line
Cable-based RF faults
150 kHz - 80 MHz
Impulse-shaped magnetic fields (OCTOPUS... Train only)
Class A
Class A
Rules f. Classification and Construction VI-7-3 Part 1
IEC 60068-2-6 Test FC, testing level in line with IEC 61131-2
Germanischer Lloyd Guidelines for the Performance of Type
Tests Part 1
IEC 870-2-2 Table 3 Normal Installation in line with EN 61850-3 Yes
EN 61373, category 1, class A (broadband noise),
installation in line with EN 50155
IEC 60068-2-27 Test Ea, test level in line with IEC 61131-2
IEC 870-2-2 Table 3 Normal Installation in line with EN 61850-3 Yes
EN 61373, category 1, class A (broadband noise),
installation in line with EN 50155
cat5e cable with 100BASE-TX
Fiber
System
attenuation
0-8 dB
Expansion Fiber data
0-5 km
1.0 dB/km, 800 MHz*km
0-4 km
1.0 dB/km, 500 MHz*km
6 kV
8 KV
20 V/m
4 kV
4 kV
1 kV
2 kV
1 kV
10 V
300
A/m
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
27