2.2

Displays

After applying the operating voltage, the software starts and initializes itself.
The device then performs a selftest. The process lasts approximately 60 se-
conds.

Device status

U
These LEDs provide information about conditions which affect the opera-
tion of the whole device.
P1- Power (green/yellow LED)
lit green
not lit
P2- Power (green/yellow LED)
lit green
not lit
1)
FAULT – Error
lit red
not lit
RM - Redundancy Manager (green/
yellow LED)
lit green
lit yellow
not lit
flashes green
1)
If the manual adjustment is active on the signal contact, then the
error display is independent of the signal contact setting.
22
OCTOPUS 24M-2FX
Device status LEDs
Meaning
the supply voltage P1 is on
supply voltage is too low
Meaning
the supply voltage P2 is on
supply voltage is too low
Meaning
the signal contact is open, i.e. it reports an error
the signal contact is closed, i.e. it does not report an
error
Meaning
RM function active, redundant port not active
RM function active, redundant port active
RM function not active
Incorrect configuration of HIPER-Ring (e.g. ring not
connected to ring port