Synchronizing the System Time in the
Network
PTPv1
PTPv2
Stratum
Clock class
number
0
– (priority 1 =
0)
1
6
2
6
3
187
4
248
5–254
–
255
255
Table 7: Stratum – classifying the clocks
Cable delays; device delays
The communication protocol specified by IEEE 1588 enables delays to be
determined. Formulas for calculating the current time eliminate delays.
Accuracy of local clocks
The communication protocol specified by IEEE 1588 takes into account
the inaccuracy of local clocks in relation to the reference clock.
Calculation formulas permit the synchronization of the local time, taking
into account the inaccuracy of the local clock in relation to the reference
clock.
Basic Configuration
Release 6.0 07/2010
Specification
For temporary, special purposes, in order to assign a higher
accuracy to one clock than to all other clocks in the network.
Indicates the reference clock with the highest degree of
accuracy. The clock can be both a boundary clock and an
ordinary clock. Stratum 1/ clock class 6 clocks include GPS
clocks and calibrated atomic clocks. A stratum 1 clock cannot be
synchronized using the PTP from another clock in the PTP
system.
Indicates the second-choice reference clock.
Indicates the reference clock that can be synchronized via an
external connection.
Indicates the reference clock that cannot be synchronized via an
external connection. This is the standard setting for boundary
clocks.
Reserved.
Such a clock should never be used as the best master clock.
7.3 Precision Time Protocol
107