Troubleshooting; Read Log; Clear Log - Animo Optivend Choco Service Enclosure

Hide thumbs Also See for Optivend Choco:
Table of Contents

Advertisement

6. TROUBLESHOOTING

WARNING
• The plug must be taken out of the socket if the appliance has to be opened for cleaning or repairs.
Introduction
Before attempting to locate the defect, check that all parts are still in place. For this purpose,
remove the rear partition of the appliance and check that all printed circuit boards, connectors,
wiring groups and hoses are still properly fitted. After carrying out a genera! inspection of the parts,
look for the possible cause of the problem on the basis of the defect analysis below.
#) If the 'Action' column advises replacing the relevant part, there is always the chance that the
defect is being caused by another problem. You will therefore need to check the function of the
appliance carefully to ensure that the defect does not recur.

6.1 Read log

During use the last 16 error reports are registered and recorded. To read these error reports activate
the Read log menu (menu 2.10). The first registration is always the most recent error report.
• The same fault codes appear in the first column as shown in the fault analysis table
(see chapter 6.4).
• In most cases this is a letter/digit combination. The level codes appear in the second column.
LVL
problem level
01
Problem solved, disturbance removed
02
Operator menu
04
Service menu
10
Hardware (NTC/flowmeter/valve)
20
Software
FF
Software registers a fault on pc board

6.2 Clear log

Use this function to erase the log menu.
service enclosure
38
01/2007 (rev. 6) V2.0