5.11.2 Using command strings

5.11.2.1 J-Link Commander
The J-Link command strings can be tested with the J-Link Commander. Use the com-
mand exec supplemented by one of the command strings.
Example
exec SupplyPower = 1
exec map reset
exec map exclude 0x10000000-0x3FFFFFFF
5.11.2.2 IAR Embedded Workbench
The J-Link command strings can be supplied using the C-SPY debugger of the IAR
Embedded Workbench. Open the Project options dialog box and select Debugger.
J-Link / J-Trace (UM08001)
© 2004-2011 SEGGER Microcontroller GmbH & Co. KG
139