Number Of Support Points - Siemens SIWAREX WP251 Manual

Electronic weighing system
Table of Contents

Advertisement

Variable
Application
Version identifier
Reserve
Reserve
Number of support
points (Page 97)
Reserve
Load cell characteristic
value (Page 98)
1)
Reserve
Rated load of a load cell
(Page 98)
1)
Reserve
Reserve
Reserve 2
Reserve 3
Reserve 4
Load cell manufacturer
string header
Load cell manufacturer
Load cell order number
String header
Load cell order number
Parameter for calculation of calibration points with theoretical calibration
1)
8.11.2

Number of support points

If no anchor points are used, the number of support points is equal to the number of load
cells.
If anchor points are used in addition to load cells, the number of support points is equal to
the total number of load cells and fixed support points.
Example
A tank is mounted on three load cells → Number of mechanical support points = 3
SIWAREX WP251
Manual, 12/2015, A5E37203357A
Note
Information about which
application the DR belongs
to
Current data record version
information
Reserve
Reserve
Number of support points
Reserve
Characteristic value of the
connected load cell(s). The
mean value (mV) is used if
there is more than one cell.
Reserve
Nominal load of one load cell FLOAT
Reserve
Reserve
Reserve
Reserve
Reserve
String header
Load cell manufacturer
String header
Load cell order number
Type
Length
Rw
(bytes)
USHORT
2
r
USHORT
2
r
USHORT
2
rw
USHORT
2
rw
USHORT
2
rw
USHORT
2
rw
FLOAT
4
rw
FLOAT
4
rw
4
rw
FLOAT
4
rw
FLOAT
4
rw
SHORT
2
rw
USHORT
2
rw
FLOAT
4
rw
UBYTE[2]
2
rw
CHAR[24] 24
rw
UBYTE[2]
2
rw
CHAR[24] 24
rw
Scale parameters and functions
8.11 DR 10 Load cell parameters
Default
Min.
Max.
105
-
-
1
1
65635
1
-
-
0
-
-
0
0
8
0
-
-
2
> 0.1 10
0
-
-
60
0
Specifi-
cation
from
DR 3
0
-
-
0
-
-
0
-
-
0
-
-
0
-
-
24,24
0.0
24,24
Modbus
registers
1402
1403
1404
1405
1406
1407
1408
1410
1412
1414
1416
1418
1419
1420
1422
1423
1435
1436
97