Messages By Leds On The Module - Siemens SIWAREX WP251 Manual

Electronic weighing system
Table of Contents

Advertisement

9.6.5

Messages by LEDs on the module

The LEDs on the front of the SIWAREX module signal the following status and error
messages.
Item
Line 1
LED 0
LED 1
LED 23
LED 3
LED 4
LED 5
LED 6
LED 7
LED 8
LED 19
LED 10
LED 11
LED 12
LED 13
LED 14
LED 15
LED 16
Line 2
LED 1
SIWAREX WP251
Manual, 12/2015, A5E37203357A
Color
Labeling
Flashing
Flashing
Flashing
Function
DIAG
System fault
Ready
Service mode is switched on
Limit 1 responded
Limit 2 responded
Limit 3 responded (empty limit)
Standstill status
Automatic weighing active
Outside of weighing range
Parameter input blocked (write protection)
Not used
LC
Load cell(s) OK
Load cell(s) faulty
Not used
Not used
Not used
Not used
Not used
Not used
AQ
Analog output active
Analog output faulty
LINK
LAN connection exists
Errors and messages