Scale parameters and functions

8.30 DR 34 ASCII weight display

8.29.2

Operating errors, technology messages, data/command errors

All available message bits are presented in the table above. For data/command errors, there
is also "Additional information" available, which is described in more detail in section
"Messages" (see Errors and messages (Page 163)).
8.30
DR 34 ASCII weight display
8.30.1

Overview

DR 34 provides an ASCII string with 16 characters, that can be used as a weight display.
The string contains both the current gross/net weight after rounding according to DR 3 as
well as the weight unit. In addition additional parameters and weight values can be
(temporarily) displayed or hidden via a command.
For applications requiring official calibration, DR 34 cannot be used as a main display. In this
case, the "SecureDisplay" software must be used in order to represent the weight and
additional information in a calibratable manner.
The corresponding registers are always currently available at the Modbus end. For operation
with a SIMATIC CPU, DR 34 must be read or requested by WP251 via a command.
Table 8- 30
Assignment of data record 34
Variable
Note
Data record num-
Contains no. of the data
ber
record
Length
Data record length infor-
mation
Application
Information about which
application the DR belongs
to
Version identifier
Current data record version
information
ASCII string header Maximum length and actual
length of string
ASCII string (page
Weight display string
119)
8.30.2

Content of the display string

The following values can be displayed:
Standard display (gross/net weight) (via command 710)
High-resolution gross/net weight (via command 701 for 5 seconds)
150
Type
Length
(bytes)
USHORT 2
USHORT 2
USHORT 2
USHORT 2
UBYTE[2
2
]
CHAR[16
16
]
Rw
Default Min. Max.
r
34
-
-
r
26
-
-
r
105
-
-
r
1
1
65635 4003
r
16,16
-
-
r
" "
-
-
From DR 30
From DR 30
Manual, 12/2015, A5E37203357A
Modbus regis-
ters
4000
4001
4002
4004
4005
SIWAREX WP251