Siemens SIWAREX WP251 Manual page 88

Electronic weighing system
Table of Contents

Advertisement

Scale parameters and functions
8.8 DR 7 Process interfaces
Variable
Note
Input filtering
0: 0.2 ms
(hardware
1: 0.2 ms
setting)
2: 0.4 ms
(Page 91)
3: 0.8 ms
4: 1.6 ms
5: 3.2 ms
6: 6.4 ms
7: 12.8 ms
Assignment of
Assignment for output 0:
digital output
Code 0 ... 0x1F hex: Bit
DQ.0, DQ.1,
no. of the status flags
DQ.2, DQ.3
from byte 0 to 3 (DR 30)
(Page 91)
Code 0x21 hex: Data
record 18
Code 0x22 hex: S7 I/O
modules
Code 0xFF hex: Output
always disabled
Assignment for output 1:
(see output 0)
Assignment for output 2:
(see output 0)
Assignment for output 3:
(see output 0)
Response of
Response of digital out-
digital outputs
puts following module
to faults or
fault or CPU STOP:
SIMATIC
0: Outputs are switched
STOP
off
(Page 92)
1: Outputs are not
switched off, continue
2: The relevant substitute
value is activated
3: The outputs are
switched on
Substitute
Substitute value for DQ 0
value for DQ
following fault or SIMATIC
0, 1, 2, 3 fol-
CPU STOP
lowing fault or
Substitute value for DQ 1
SIMATIC
following fault or SIMATIC
STOP
CPU STOP
(Page 92)
Substitute value for DQ 2
following fault or SIMATIC
CPU STOP
Substitute value for DQ 3
following fault or SIMATIC
CPU STOP
Bit 4
Reserve
Bit 5
Reserve
88
Type
Length
RW
(bytes)
USHORT
2
rw
USHORT
2
rw
USHORT
2
rw
USHORT
2
rw
USHORT
2
rw
USHORT
2
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
Default
Min.
Max.
5
0
7
0
0
0xFFFF
0
0
0xFFFF
0
0
0xFFFF
0
0
0xFFFF
0
0
0
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
Manual, 12/2015, A5E37203357A
Modbus
Register
1308
1309
1310
1311
1312
1313
1314.16
1314.15
1314.14
1314.13
1314.12
1314.11
SIWAREX WP251