Date, Time; Dr 47 Logbook - Siemens SIWAREX WP251 Manual

Electronic weighing system
Table of Contents

Advertisement

Designation
Additional string
SEMICOLON
8.36.6

Date, time

The date and time of the selected log are displayed here.
8.37

DR 47 Logbook

The changes in the SecureDisplay software versions are recorded in the logbook. If the
SIWAREX has established communication with the SecureDisplay, SIWAREX checks
whether the software version of the SecureDisplay has changed. Changes are recorded in
the logbook. In this way, a more recent version of the SecureDisplay can also be used during
operation requiring calibration without the calibration being violated.
The logbook entries are in data record 47. Scrolling in the logbook is possible using
commands 881 to 883: → Command list (page 135). Calibratable reading of the logbook is
carried out using the SecureDisplay.
Table 8- 38
Assignment of data record 47
Tag
Data record number
Length
Application
Version identifier
String header for oldest log
book ID
Oldest log book ID
String header of youngest
logbook ID
Youngest logbook-ID
String header for selected
logbook ID
ID of the selected logbook
entry
String header for device
SIWAREX WP251
Manual, 12/2015, A5E37203357A
Comments
Contains no. of the data
record
Data record length infor-
mation
Information about which
application the data record
belongs to
Current data record ver-
sion information
String header
ID of first logbook entry
String header
ID of last logbook entry
String header
ID of the selected logbook
entry
String header
Data type
UBYTE
UBYTE
Type
Length
Rw De-
(bytes)
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
UBYTE[2]
2
r
CHAR[8]
8
r
UBYTE[2]
2
r
CHAR[8]
8
r
UBYTE[2]
2
r
CHAR[8]
8
r
UBYTE[2]
2
r
Scale parameters and functions
8.37 DR 47 Logbook
Length
16
1
Min.
Max.
fault
47
72
105
1
1
65635
8,8
"0"
1
99999999
8,8
"0"
1
99999999
8,8
"0"
1
99999999
4,4
Modbus
register
4392
4393
4394
4395
4396
4397
4401
4402
4406
4407
4411
159