Overview

Data record DR 7 contains the parameters for defining the properties of the available I/O
modules (digital inputs, digital outputs, analog output, serial ports).
If a port is not used, the default values can be retained.
Table 8- 5
Assignment of data record 7
Variable
Note
Data record
Contains no. of the data
number
record
Length
Data record length infor-
mation
Application
Information about which
application the DR be-
longs to
Version identi-
Current data record ver-
fier
sion information
Assignment of
Code 0: No command
digital input
assigned
DI.0, DI.1,
1....32759 Command is
DI.2, DI.3
triggered at a positive
(Page 90)
edge
32760...32767: Transition
for steps 0 to 7 (positive
edge)
32769 ... 65527 Com-
mand (command
code+32768) is triggered
at a negative edge
65528...65535: Transition
for steps 0 to 7 (negative
edge)
86
Type
Length
RW
(bytes)
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
rw
Default
Min.
Max.
7
-
-
60
-
-
105
-
-
1
1
65635
0
0
1999
Manual, 12/2015, A5E37203357A
Modbus
Register
1300
1301
1302
1303
1304