Data And Command Errors - Additional Information - Siemens SIWAREX WP251 Manual

Electronic weighing system
Table of Contents

Advertisement

Errors and messages
9.6 Operating errors
9.6.4

Data and command errors - Additional information

Additional information is available for most data/command errors. The cause of the error is
described in detail with this information. If a data/command error bit is set, the additional
information is also filled accordingly. Thus, the error bits and the additional information must
be evaluated together in the program to identify the exact cause of the error.
If additional information not listed above appears for a data/operating error bit, it is a
parameter ID. This defines the exact parameter that caused the error.
The following table presents the association between the parameter and parameter ID.
Parameter
Standstill 1 - range
Standstill 2 - range
Standstill 1 - time
Standstill 2 - time
Weighing operating mode
Automatic zero tracking
Calibration digits 0 (measured)
Calibration digits 1 (measured)
Calibration digits 2 (measured)
Calibration weight 0
Calibration weight 1
Calibration weight 2
Depth average filter
Frequency low pass filter 1
SecureDisplay version
SecureDisplay interface
Gross indicator
Maximum weight
Minimum weight
Order no. low pass filter 1
Automatic zero tracking in dosing cycle
Resolution
Restriction code
Scale name
Additive tare
Grid frequency
Tare maximum
Max. waiting time for standstill 1
Weight simulation allowed
Weight unit
Initial zeroing
Initial zeroing if tared
Negative zeroing limit (initial zeroing)
172
Data record
Parameter ID
3
2153
3
2154
3
2158
3
2159
3
2503
3
3063
3
3081
3
3083
3
3085
3
3086
3
3087
3
3088
3
3137
3
3175
3
3178
3
3197
3
3199
3
3217
3
3219
3
3236
3
3247
3
3248
3
3249
3
3256
3
3282
3
3283
3
3288
3
3316
3
3322
3
3323
3
3329
3
3330
3
3332