Siemens SIWAREX WP251 Manual page 112

Electronic weighing system
Table of Contents

Advertisement

Scale parameters and functions
8.21 DR 22 Tolerance parameters
Variable
Parameter
relation
(Page 115)
Reserve
Tolerance limit
TH2 (Page 116)
Tolerance limit
TH1 (Page 116)
Tolerance limit
TL1 (Page 116)
Tolerance limit
TL2 (Page 116)
Reserve
112
Note
Data type
0: Tolerance specifi-
USHORT
cations are to be
interpreted as per-
centages (referenc-
ing the set point in
DS 20) (default)
1: Tolerance specifi-
cations are to be
interpreted as abso-
lute (as weight val-
ue)
2: Tolerance limits
are derived from
OIML table "Limits of
error on verification
Class X1" (for AWI
mode)
3: Tolerance limits
are derived from
OIML table "Maxi-
mum permissible
errors in service
Class X1" (for AWI
mode)
Reserve
USHORT
High limit tolerance
FLOAT
band 2 (outer)
High limit tolerance
FLOAT
band 1 (inner)
Low limit tolerance
FLOAT
band 1 (inner)
Low limit tolerance
FLOAT
band 2 (outer)
Reserve
USHORT
Length
RW De-
Min
(bytes)
fault
2
rw
0
0
2
rw
0
0
4
rw
2
0
4
rw
1
0
4
rw
1
0
4
rw
2
0
2
rw
0
0
Manual, 12/2015, A5E37203357A
Max
Modbus
registers
0
1648
0
1649
0
1650
0
1652
0
1654
0
1656
0
1658
SIWAREX WP251