Dr 23 Material Parameters; Overview - Siemens SIWAREX WP251 Manual

Electronic weighing system
Table of Contents

Advertisement

Scale parameters and functions

8.22 DR 23 Material parameters

8.22
DR 23 Material parameters
8.22.1

Overview

Material-specific parameters are specified in the data record.
Table 8- 22
Assignment of data record 23
Variable
Note
Data record
Contains no. of the data record
number
Length
Data record length information
Application
Information about which applica-
tion the data record belongs to
Version
Current data record version infor-
identifier
mation
Parameter
0: Trailing/fine weight is interpret-
relation
ed as % of set point (DR 20) (de-
(Page 119)
fault)
1: Trailing/fine weight is interpret-
ed as absolute weight value
Reserve
Reserve
Fine weight
Material quantity that is to be
(Page 119)
dosed in fine flow
Trailing
Material quantity that still runs
weight
after shut-off of the fine flow
(Page 119)
Blocking
Blocking time after switch-off of
time coarse
coarse signal
signal
(Page 120)
Blocking
Blocking time after switch-off of
time fine
fine signal
signal
(Page 120)
Shut-off
Shut-off correction value for com-
correction
pensation of influences such as
weight
overpressure or underpressure
(Page 121)
when dosing
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
118
Type
Length
RW
(bytes)
USHORT
2
R
USHORT
2
R
USHORT
2
R
USHORT
2
R
USHORT
2
RW
USHORT
2
RW
FLOAT
4
RW
FLOAT
2
RW
TIME
4
RW
TIME
4
RW
FLOAT
4
RW
FLOAT
4
RW
FLOAT
4
RW
USHORT
2
RW
USHORT
2
RW
Default
Min.
Max.
20
-
-
20
-
-
105
-
-
1
1
65635
0
0
1
-
-
-
20
0
-
5
0
-
0
0
0
0
0
0
-
-
-
-
-
-
-
-
-
-
-
-
-
Manual, 12/2015, A5E37203357A
Modbus
registers
1672
1673
1674
1675
1676
1677
1678
1680
1682
1684
1686
1688
1690
1692
1693
SIWAREX WP251