Table 10- 2 Protocol Commands, Statistics, Logbook - Siemens SIWAREX WP251 Manual

Electronic weighing system
Table of Contents

Advertisement

Com-
Command
mand
code
83
Check Calibration
443
Reset min/max pointer
Table 10- 2
Protocol commands, statistics, logbook
Com-
Command
mand
code
401
Generate protocol
405
Erase protocols
440
Erase log book
Table 10- 3
Trace commands
Command
Command
code
451
Trace ON
452
Trace OFF
453
Single Trace Element
454
Reset Trace Memory
Table 10- 4
Display changeover for DR 34 and SecureDisplay
Command
Command
code
701
High resolution on
705
Display Tare Process
710
Display standard weight
721
Display single set point
SIWAREX WP251
Manual, 12/2015, A5E37203357A
Description
The command calculates the theoretical digit values in relation to the cali-
bration weights using the load cell parameters from data record 10 and the
calibration weights 0, 1 and 2 from data record 3. These theoretical digits
are output in data record 4. The function can be used to compare the cali-
bration digits in data record 3 that were determined during a calibration
with calibration weights (commands 60, 61, 62) with the theoretically ex-
pected digits.
Resets the weight min/max pointer in DR 38
Description
Log current parameters relevant to the calibration
Delete all logs
Delete the logbook. Only permitted in non-calibrated state.
Description
Start trace recording
Stop trace recording
Create single trace (current state)
Delete trace memory
Description
Activate high resolution (factor 10) of the weight value
on the main display (DR 34) and the SecureDisplay
for 5 s.
Display current tare weight on the main display (DR
34) and the SecureDisplay.
Display standard gross/net weight display on the
main display (DR 34) and the SecureDisplay.
Display currently set point setting from DR 20 on the
main display (DR 34) and the SecureDisplay for 5
seconds.
Command lists
10.2 Command lists
Pro-
tected
P
Protected
P
P
Protected
Protected
181