Siemens SIWAREX WP251 Manual page 101

Electronic weighing system
Table of Contents

Advertisement

Variable
Note
RS485
0: 1 200 bps
baud rate
1: 2 400 bps
(Page 102)
2: 9 600 bps
3: 19 200 bps
4: 38 400 bps
5: 57 600 bps
6:115 000 bps
RS485
Character parity
character
0: Even
parity
1: Odd
(Page 102)
RS485
Number of data bits per
number of
character
data bits
0: 7 data bits
(Page 102)
1: 8 data bits
RS485
Number of stop bits
number of
0: 1 stop bit
stop bits
1: 2 stop bits
(Page 103)
Bit 3
Reserve
Bit 4
Reserve
Bit 5
Reserve
Bit 6
Reserve
Bit 7
Reserve
Bit 8
Reserve
Bit 9
Reserve
Bit 10
Reserve
Bit 11
Reserve
Bit 12
Reserve
Bit 13
Reserve
Bit 14
Reserve
Bit 15
Reserve
RS485
MODBUS address for Vito
Modbus
module
address
(Page 103)
Decimal
Decimal place for Siebert
place for
display
Siebert
indicator
(Page 103)
MODBUS
Delay time for response with
RTU frame
MODBUS RTU in ms
delay
(RS485)
Reserve 3
Reserve
SIWAREX WP251
Manual, 12/2015, A5E37203357A
Type
Length
Rw
(bytes)
USHORT
2
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
2
rw
USHORT
2
rw
SHORT
2
rw
USHORT
2
rw
FLOAT
4
rw
Scale parameters and functions
8.13 DR 13 RS485 parameters
Default Min.
Max.
2
0
6
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
20
1
255
0
-
-
0
-
-
0
-
-
Modbus
registers
1563
1564.16
1564.15
1564.14
1564.13
1564.12
1564.11
1564.10
1564.9
1564.8
1564.7
1564.6
1564.5
1564.4
1564.3
1564.2
1564.1
1565
1566
1567
1568
101