Table 10- 5 Scale Commands - Siemens SIWAREX WP251 Manual

Electronic weighing system
Table of Contents

Advertisement

Table 10- 5
Scale commands
Command
Command
code
1001
Zero
1011
Tare
1012
Delete Tare
1013
Activate Preset Tare 1
1016
Activate Preset Tare S7
Table 10- 6
Scale commands
Command
Command
code
1101
Start single
weighing
1103
Start continuous
mode
1121
Stop weighing
1122
Activate check
stop
1123
Stop continuous
mode
1124
Abort weighing
1125
Rest weighing
1126
Manual emptying
ON
SIWAREX WP251
Manual, 12/2015, A5E37203357A
Description
Set to zero (semi-automatic)
Taring (semi-automatic)
Delete current tare weight
Preset tare weight value from DR 15 is transferred
Preset tare weight value from SIMATIC I/O interface
(see section I/O interface of function block
(Page 191)) is transferred.
Description
Starts an individual dosing cycle.
Starts n dosing cycles in continuous succession Continuous operation
ends automatically if a total set point (DR 21) was specified and reached
or alternatively using the "Stop continuous mode (1123)" command. If a
dosing cycle is still active, it is completed. The "Abort weighing (1124)"
command also ends continuous operation but does not terminate an
active dosing cycle.
The "Continuous mode active" bit in the AWI Status (DR 30) indicates
whether or not WP251 is operating in continuous mode.
Current dosing cycle is stopped and the "Weighing cycle stopped" bit is
set in the AWI Status (DR 30). The "Continue weighing (1141)" command
can be used to continue and thus complete the cycle from this status.
If check stop points have been defined (see section I/O interface of func-
tion block (Page 191)), these are activated by "Activate check stop" and
the dosing cycle stops at the predefined points.
Continuous operation is stopped. If the command is issued within a dos-
ing cycle, this dosing cycle is first finished and WP251 then waits in
weighing step 0. The "Continuous mode active" bit in the AWI Status (DR
30) is reset.
The current dosing cycle is directly aborted and WP251 jumps immedi-
ately to weighing step 0.
The command can be issued within the dosing cycle or outside of it
(=weighing step 0). Any active coarse or fine signal is directly reset, a
tolerance check is performed, a log print is created and – if configured in
DR 25 –the scale is emptied. WP251 then waits in weighing step 0.
The command can be issued only in weighing step 0. The "Emptying
signal" bit is then set to TRUE and a linked digital output, if any, is set.
The command is used to clean the scale or to open it manually for ser-
vice.
Command lists
10.2 Command lists
Protected
Protected
183