Scale parameters and functions

8.13 DR 13 RS485 parameters

8.12.5

Subnet mask

Assign the subnet mask of your network.
8.12.6

Gateway

If a gateway is used between the SIWAREX WP251 and the communication partner, enter
the gateway address here.
If a gateway is not present, enter the IP address of the SIWAREX module.
8.12.7

Device name

This parameter can be used to assign a name to the weighing module in the Ethernet
network. The length of the name is limited to 32 characters. Empty spaces must be filled by
"x".
8.13
DR 13 RS485 parameters
8.13.1

Overview

The parameter assignment of the RS485 interface occurs in data record DR 13. If the
interface is not used, the default values can be retained.
Table 8- 12
Assignment of data record 13
Variable
Note
Data record
Contains no. of the data
number
record
Length
Data record length infor-
mation
Application
Information about which
application the data record
belongs to
Version
Current data record version
identifier
information
RS485
0: No protocol
protocol
1: MODBUS RTU
(Page 102)
2: SIEBERT display
100
Type
Length
Rw
(bytes)
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
rw
Default Min.
Max.
13
-
-
24
-
-
105
-
-
1
1
65635
1
0
2
Manual, 12/2015, A5E37203357A
Modbus
registers
1558
1559
1560
1561
1562