c. Switch to the system console to view POST output.
-> start /HOST/console
.
.
.
0:7:2>INFO:
0:7:2>
0:7:2>POST:
0:7:2>Master set ACK for vbsc runpost command and spin...
Note – The system might boot automatically at this point. If so, go directly to
If it remains at the ok prompt go to
d. If the server module remains at the ok prompt, type boot.
e. Return the virtual keyswitch to Normal mode.
-> set /SYS keyswitch_state=Normal
Set 'ketswitch_state' to 'Normal'
f. Switch to the system console and type the Oracle Solaris OS fmadm faulty
# fmadm faulty
5. Switch to the Oracle ILOM command shell.
80
SPARC T3-1B Server Module Service Manual • July 2012
Watch the POST output for possible fault messages. The following output
indicates that POST did not detect any faults:
POST Passed all devices.
Return to VBSC.
command.
If any faults are reported, see the diagnostics instructions in
Troubleshooting Overview" on page