2. Set the virtual keyswitch to the value that corresponds to the POST
configuration you want to run.
The following example sets the virtual keyswitch to normal, which will configure
POST to run according to other parameter values.
-> set /SYS keyswitch_state=normal
Set 'keyswitch_state' to 'Normal'
For possible values for the keyswitch_state parameter, see
Properties That Affect POST Behavior" on page
3. If the virtual keyswitch is set to normal, and you want to define the mode,
level, verbosity, or trigger, set the respective parameters.
Syntax:
set /HOST/diag property=value
See
parameters and values.
Examples:
-> set /HOST/diag mode=normal
or
-> set /HOST/diag verbosity=max
4. To see the current values for settings, use the show command.
Example, showing default values:
-> show /HOST/diag
/HOST/diag
36
SPARC T3-1B Server Module Service Manual • July 2012
"Oracle ILOM Properties That Affect POST Behavior" on page 33
Targets:
Properties:
error_reset_level = max
error_reset_verbosity = normal
hw_change_level = max
hw_change_verbosity = normal
level = max
mode = normal
power_on_level = max
power_on_verbosity = normal
trigger = hw-change error-reset
verbosity = normal