Oracle ILOM Properties That Affect POST
Behavior
The following table describes the Oracle ILOM properties that determine how POST
performs its operations.
Note – The value of keyswitch_state must be normal when individual POST
parameters are changed.
Parameter
/SYS keyswitch_state
/HOST/diag mode
/HOST/diag level
/HOST/diag trigger
/HOST/diag verbosity
Values
normal
diag
standby
locked
off
normal
service
max
min
none
hw-change
power-on-reset
error-reset
all-resets
normal
min
Description
The system can power on and run POST (based on the
other parameter settings). This parameter overrides
all other commands.
The system runs POST based on predetermined
settings.
The system cannot power on.
The system can power on and run POST, but no flash
updates can be made.
POST does not run.
Runs POST according to diag level value.
Runs POST with preset values for diag level and
diag verbosity.
If diag mode = normal, runs all the minimum tests
plus extensive processor and memory tests.
If diag mode = normal, runs minimum set of tests.
Does not run POST on reset.
(Default) Runs POST following an AC power cycle
and when the top cover is removed.
Only runs POST for the first power on.
(Default) Runs POST if fatal errors are detected.
Runs POST after any reset.
POST output displays all test and informational
messages.
POST output displays functional tests with a banner
and pinwheel.
Detecting and Managing Faults