/SP/faultmgmt/0
faults/0
->
Example of the show faulty command displaying a fault that was detected by
■
POST. These kinds of faults are identified by the message Forced fail reason,
where reason is the name of the power-on routine that detected the fault.
-> show faulty
Target
--------------------+------------------------+--------------------------------
/SP/faultmgmt/0
/SP/faultmgmt/0/
faults/0
/SP/faultmgmt/0/
faults/0
Example of the show faulty command displaying a fault that was detected by
■
the PSH technology. These kinds of faults are identified by the presence of a
UUID value.
-> show faulty
Target
--------------------+------------------------+--------------------------------
/SP/faultmgmt/0
/SP/faultmgmt/0
/SP/faultmgmt/0/
faults/0
/SP/faultmgmt/0/
faults/0
/SP/faultmgmt/0/
faults/0
Related Information
"Diagnostics Process" on page 7
■
"Access the SP (Oracle ILOM)" on page 15
■
"Display FRU Information (show Command)" on page 17
■
"Check for Faults (fmadm faulty Command)" on page 20
■
"Clear Faults (clear_fault_action Property)" on page 21
■
"Service-Related Oracle ILOM Command Summary" on page 21
■
| chassis_serial_number
|
| Property
| fru
| timestamp
|
| sp_detected_fault
| Property
| fru
| timestamp
| sunw-msg-id
|
| uuid
|
| timestamp
|
| 0000000-0000000000
|
| Value
| /SYS/MB/CMP0/BOB1/CH0/D0
| Oct 12 16:40:56
|
| /SYS/MB/CMP0/BOB1/CH0/D0
| Forced fail(POST)
| Value
| /SYS/MB/CMP0/BOB0/CH0/D0
| Mar 29 22:43:59
| SUN4V-8000-DX
|
| 3aa7c854-9667-e176-efe5-e487e520
| 7a8a
| Mar 29 22:43:59
|
Detecting and Managing Faults