2. Take one of the following actions based on the show faulty output:
No fault is reported – The system cleared the fault and you do not need to
manually clear the fault. Do not perform the subsequent steps.
Fault reported – Go to the next step in this procedure.
3. Use the component_state property of the component to clear the fault and
remove the component from the ASR blacklist.
Use the FRU name that was reported in the fault in
-> set /SYS/MB/CMP0/BOB1/CH0/D0 component_state=Enabled
The fault is cleared and should not show up when you run the show faulty
command. Additionally, the front panel Fault (Service Action Required) LED is no
longer on.
4. Reset the server module.
You must reboot the server module for the component_state property to take
effect.
5. At the Oracle ILOM prompt, use the show faulty command to verify that no
faults are reported.
Example:
-> show faulty
Target
--------------------+------------------------+------------------
->
Related Information
"POST Overview" on page 32
"Oracle ILOM Properties That Affect POST Behavior" on page 33
"Configure How POST Runs" on page 35
"Run POST With Maximum Testing" on page 37
"Clear POST-Detected Faults" on page 40