Advertisement

5. Push the DIMM into the connector until the ejector tabs lock the DIMM in
place.
If the DIMM does not easily seat into the connector, verify that the orientation of
the DIMM is correct. Never apply excessive force.
6. Return the server module to operation.
See
"Returning the Server Module to Operation" on page 111
7. Perform one of the following tasks to verify the DIMM:
Verify a replacement DIMM. See
of the Replacement DIMM" on page
Verify additional memory. See
Related Information
"Remove a DIMM" on page 73
"DIMM Configuration Reference" on page 81
▼ Clear the Fault and Verify the
Functionality of the Replacement
DIMM
This procedure describes how to clear a memory fault and how to verify the
functionality of the replacement DIMM.
Ensure that the following conditions are met:
The server module is in Standby mode (installed in a powered modular system,
but the server module's host is not started).
See
"Prepare the Server Module for Removal" on page
You have connectivity to the SP.
See
"Access the SP (Oracle ILOM)" on page 15
1. Access the Oracle ILOM -> prompt.
See
"Access the SP (Oracle ILOM)" on page
"Clear the Fault and Verify the Functionality
75.
"Verify DIMM Functionality" on page
15.
79.
58.
Servicing Memory
75