3-12
Programming and Parameters
No. Parameter Name and Description
071 [Break Voltage]
Sets the voltage the drive will output at
[Break Frequency].
Refer to parameter 083 [Overspeed Limit].
072 [Break Frequency]
Sets the frequency the drive will output at
[Break Voltage].
Refer to parameter 083 [Overspeed Limit].

Speed Command File (File C)

No. Parameter Name and Description
080 [Speed Mode]
Sets the method of speed regulation.
081 [Minimum Speed]
Sets the low limit for speed reference after
scaling is applied.
Refer to parameter 083 [Overspeed Limit].
082 [Maximum Speed]
Sets the high limit for speed reference
after scaling is applied.
Refer to parameter 083 [Overspeed Limit].
083 [Overspeed Limit]
Sets the incremental amount of the output
frequency (above [Maximum Speed])
allowable for functions such as slip
compensation.
[Maximum Speed] + [Overspeed Limit]
must be ≤ [Maximum Freq]
Max Volts
Motor Volts
Break Volts
Start Boost
Allowable Output Frequency Range
Bus Regulation or Current Limit
Allowable Output Frequency Range
Allowable Reference Frequency Range
Frequency Trim due to
Speed Control Mode
Run
0
Min
Break
Speed
Frequency
Values
[Motor NP Volts] × 0.25
Default:
Min/Max:
0.0/[Motor NP Volts]
Display:
0.1 VAC
[Motor NP Freq] × 0.25
Default:
Min/Max:
0.0/[Motor NP Freq]
Display:
0.1 Hz
Values
Default:
0
Options:
0
1
2
Default:
0.0 Hz
Min/Max:
0.0/[Maximum Speed]
Display:
0.1 Hz
Default:
50.0 or 60.0 Hz
(Dependent on voltage
class)
Min/Max:
5.0/400.0 Hz
Display:
0.0 Hz
Default:
10.0 Hz
Min/Max:
0.0/20.0 Hz
Display:
0.1 Hz
Normal Operation
Overspeed
Motor
Hz
Frequency
"Open Loop"
"Open Loop"
"Slip Comp"
"Process PI"
Limit
Max
Output
Max
Speed
Freq Limit
Freq
053
072
053
071
121
thru
138
092
095
055
083
091
094
202
055
082

Hide quick links: