Allen-Bradley PowerFlex 70 User Manual page 21

Adjustable frequency
Hide thumbs Also See for PowerFlex 70:
Table of Contents

Advertisement

Figure 1.3 Power Terminal Block and DC Bus Test Points
Terminal
Description
R
R (L1)
S
S (L2)
T
T (L3)
+DC
DC Bus (+)
BRK
DC Brake
U
U (T1)
V
V (T2)
W
W (T3)
PE
PE Ground
PE
PE Ground
DC Bus Test Points
-DC Test Point
Description
DC Bus (–)
DC Bus (–)
Figure 1.4 Power Input Terminals on the Internal RFI Filter Option
L1
L2
L3
R
S
T
Cable Entry Plate Removal
If additional wiring access is needed, the Cable Entry Plate on all drive
Frames can be removed. Simply loosen the screws securing the plate to
the heat sink and slide the plate out.
-DC
L1
L2
L3
+DC BRK T1
R
S
T
Notes
AC Line Input Power
AC Line Input Power
AC Line Input Power
Dynamic Brake Resistor Connection (+)
Dynamic Brake Resistor Connection (–)
To Motor
To Motor
To Motor
Notes
Location on A and B Frame drives
Location on C and D Frame drives
-DC
L1
L2
L3
+DC BRK T1
R
S
T
Installation/Wiring
-DC
T2
T3
PE
PE
U
V
W
-DC
T2
T3
PE
PE
U
V
W
1-9

Hide quick links:

Advertisement

Table of Contents
loading