Thermal Dynamics CUTMASTER 60i Service Manual page 72

Plasma cutting system
Hide thumbs Also See for CUTMASTER 60i:
Table of Contents

Advertisement

CUTMASTER 60i
Optional Two-Stage Filter Element Replacement
The Two-Stage Air Filter has two Filter Elements. When the Filter Elements become dirty the Power Supply will
continue to operate but cut quality may become unacceptable. Refer to Section 6, Parts List, for replacement filter
element catalog number.
1. Shut OFF primary input power.
2. Shut OFF air supply and bleed down system.
3. Loosen the two bolts on the top of the Filter Assembly enough to allow the Filter Elements to move freely.
4. Note the location and orientation of the old Filter Elements.
5. Slide out the old Filter Elements.
6. Slide the replacement Filter Elements into the Filter Assembly, with the same orientation as noted in Step 4
above.
7. Hand tighten the two bolts evenly, then torque each bolt to 20 - 30 in-lbs (2.3 - 3.4 Nm). Improper torque
may damage the gasket.
8. Slowly apply air pressure to the assembly, checking for leaks.
5-38
WARNING
!
Always turn OFF the air supply and bleed
the system before disassembling the Filter
Assembly as injury could result.
First & Second
Stage
Cartridges
(as marked)
Optional Two-Stage Filter Replacement
NOTE!
A small amount of air leakage from the bot-
tom fitting is normal.
NOTE!
Filter replacement part numbers can be
found in Section 6 of this manual
SERVICE
Art # A-02942
Manual 0-5475