Thermal Dynamics CUTMASTER 60i Service Manual page 15

Plasma cutting system
Hide thumbs Also See for CUTMASTER 60i:
Table of Contents

Advertisement

3 Phase
Input Power
3 Phase Input Power Cable
Output Current
Power Supply Gas Filtering
Maximum Inlet Pressure
Ambient Air Temperature
* NOTE: The duty cycle will be reduced if the primary input power (AC) is low or the
Recommended
Generator Recommendations
When using generators to power the 60i Plasma Cutting System, the following ratings are a minimum and are to
be used along with the ratings listed above.
Generator Output Rating
Manual 0-5475
60i 3 Phase Power Supply Specifications
208 - 480 VAC(187 - 528 VAC), 3 Phase, 50/60 Hz
Power Supply includes 9' single phase 12AWG 4/C input
Ability
60i Power Supply Duty Cycle *
Duty Cycle
All Units
Current
DC Voltage
output voltage (DC) is higher than shown in this chart.
60i Cut Capacity
5/8"
A60i Generator Specifications
15 kW
12 kW
10 kW
NOTE!
Due to circuitry, age and condition two generators with the same ratings
may produce different results. Adjust the amperage accordingly.
INTRODUCTION
cable without plug..
10 - 60 Amps, Continuously Adjustable
Particulates to 5 Microns
125 PSI (8.6 bar)
Duty Cycle Ratings @ 40° C (104° F)
Operating Range 0° - 50° C
Rating
50%
60%
60 Amps
50 Amps
126
122
Pierce
5/8"
60i Output Current
60A
60A
45A
45A
30A
CUTMASTER 60i
100%
40 Amps
119
Maximum
1 1/4"
Arc Characteristic
Full
Limited
Full
Limited
Full
2-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents