3 Phase
3 Phase CutMaster 60i Power Supply Input Cable Wiring Requirements
Input voltage
Volts
208
230
380
3 Phase
400
415
480
2.06
Power Supply Features
Art # A-13258
Manual 0-5475
Freq
Power Input
Hz
kVA
50/60
9.1
50/60
9.1
50/60
8.9
50/60
8.9
50/60
9.1
50/60
9.2
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
NOTE!
Refer to Local and National Codes or local authority having jurisdiction for
proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
Handle and Leads Wrap
Input Power ON/OFF Switch
Input Power Cord
Port for Optional Automation
Interface Cable
Gas Inlet Port
Filter Assembly
INTRODUCTION
I max
I
eff
1
26
18.5
23.3
16.5
13.8
9.8
13.2
9.4
12.8
9.1
11.3
8.0
Three Phase
Control Panel
Torch Leads Receptacle
Work Lead Receptacle
Art # A-13275
CUTMASTER 60i
Suggested Sizes
Flexible Cord (Min.
Fuse (amps)
AWG)
40
12 AWG (2.5mm
30
12 AWG (2.5mm
20
14 AWG (2.5mm
20
14 AWG (2.5mm
20
16 AWG (1.5mm
15
16 AWG (1.5mm
)
2
)
2
)
2
)
2
)
2
)
2
2-5