Thermal Dynamics CUTMASTER 60i Service Manual page 46

Plasma cutting system
Hide thumbs Also See for CUTMASTER 60i:
Table of Contents

Advertisement

CUTMASTER 60i
2. Measure bridge rectifier diodes
On diode scale measure from each of the three AC terminals to GND_PRI .then measure each of the AC terminals
to the terminal next on the right of BRIDGE+. .
5-12
+15V
J303
+
6
4
+24V
3
1
HS302
Art # A-13326
D307
C307
SERVICE
E300
CHASSIS
GND
GRN/YEL
MOV300 MOV301 MOV302
MOV304
MOV305
GND PRI
BRIDGE+
TP8
TP23
15 UV
LO LINE
R300
1
J302
TP22
D302
+
HI LINE
TP4
TP21
ACINSEN
BUS CHK
+15V PRI
T300
D303
1
C301
C300
R302
1
T301
C303
D304
C305
J304
-15V
1
1
1
K300
MOV306
R301
R303
C302
J305
Manual 0-5475