KEB COMBIVERT F4-C Applications Manual page 81

Hide thumbs Also See for COMBIVERT F4-C:
Table of Contents

Advertisement

Operating and Appliance Displays
ru.15 Output terminal status
Adr.
200Fh
Display of the currently set external and internal digital outputs. Whether the outputs are set by inverting or real is
irrelevant for the display. According to following table a certain decimal value is given out for each digital output. If
several outputs are set then the sum of their decimal values is displayed.
Bit -No.
ru.16 Internal input status
Adr.
2010h
Display of the currently set external and internal digital inputs. The input is considered as set when it is available as
active signal for further processing (i.e. acceptance by strobe, edge triggering or logic operation). According to following
table a certain decimal value is given out for each digital input. If several inputs are set then the sum of their decimal
values is displayed.
Bit -No.
©
KEB Antriebstechnik, 1999
All Rights reserved
min
max
0
255
Decimal value
0
1
1
2
2
4
4
16
5
32
6
64
7
128
min
max
0
4095
Decimal value
0
1
1
2
2
4
3
8
4
16
5
32
6
64
7
128
8
256
9
512
10
1024
11
2048
Name: Basis
KEB COMBIVERT F4-C
Functional Description
-
1
Output
Out 1 (transistor output)
Out 2 (relay RLA,RLB,RLC)
Out 3 (relay FLA,FLB,FLC)
Out A (internal output A)
Out B (internal output B)
Out C (internal output C)
Out D (internal output D)
1
Input
ST (control release)
RST (reset)
F (rotation forward)
R (rotation reverse)
I1 (prog. input 1)
I2 (prog. input 2)
I3 (prog. input 3)
I4 (prog. input 4)
IA (internal input A)
IB (internal input B)
IC (internal input C)
ID (internal input D)
09.04.99
ANTRIEBSTECHNIK
default
-
Terminal
12
1 , 2 , 3
21 , 22 , 23
none
none
none
none
default
-
-
Terminal
19
20
10
11
4
5
6
7
none
none
none
none
Date
Chapter
Section
6
1
6
Page
11
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents