Operation
Setpoint signal
Section
Page
Chapter
4
3
12
The setpoint input REF (terminal X1.17) can be triggered with different signal levels.
It acts adding to the differential voltage input (terminal X1.8 and X1), but can also
serve as sole input for the setpoint value adjustment. To evaluate the signal correctly,
the parameter must be adapted to the signal source.
Value
Setpoint signal
0
0...10 V DC / Ri = 4 kOhm
1
0...20 mA DC / Ri = 250 Ohm
2
4...20 mA DC / Ri = 250 Ohm
Factory setting:
Customer setting:
Date
Name: Basis
KEB COMBIVERT F4-C
20.03.98
CP - Parameter
f
CP.10
CP. 9
0
0 V
0 mA
_______
4 mA
©
KEB Antriebstechnik, 1997
All Rights reserved
U
Ref
10 V
20 mA
20 mA