KEB COMBIVERT F4-C Applications Manual page 28

Hide thumbs Also See for COMBIVERT F4-C:
Table of Contents

Advertisement

Hardware
3.1.2
Control Cards
0A.F4.080-xxxx
Missing parameters:
- ru.46
Ramp output frequency
- ru.47
Actual frequency of speed detection
- oP.30 Motor-poti / prescaler
- oP.31 Motor-poti / target
- oP.32 Max. output freq. clockwise rotation
- oP.33 Max. output freq. counter-clockwise rotation
- Pn.51 Brake control / mode
- Pn.52 Brake control / starting time 1
- Pn.53 Brake control / starting time 2
- Pn.54 Brake control / starting frequency
- Pn.55 Brake control / stopping time 1
- Pn.56 Brake control / stopping time 2
- Pn.57 Brake control / stopping frequency
- Pn.58 Brake control / load level
- LE.69 Hysteresis analog inputs
Parameters with limited value range:
- oP.0
Setpoint value source value 21...26 missing
- cn.0
Controller selection Bit 3...7 missing
- Pn.33 Power-Off mode
- Pn.50 Speed search mode
- An.14 Function analog output
Specifications
Chapter
Section
Page
3
1
4
This control card is used in D and E units when no speed detection is required. The
following changes in the parameter and function description have to be taken into
account:
- 1 programmable transistor output 14...30VDC / max. 20mA
- 2 programmable relay outputs 30VDC / 1A
- 4 programmable digital inputs 12...30VDC ±0% / R
- 4 non-adjustable digital inputs 12...30VDC ±0% / R
- 1 analog output 0...10VDC / max. 5mA at R
- 1 multi-function analog input 0...10V, 0...20mA or 4...20mA
- 1 differential voltage input ±10VDC
- 1 voltage ouput +15VDC / max. 100 mA for the supply of the digital inputs and
outputs
- 1 voltage output +10VDC / max. 4mA for the supply of the setpoint value poti
Date
Name: Basis
KEB COMBIVERT F4-C
09.02.98
- di.21
Reset ST Mode
- cn.3
Source actual speed
- dr.22
Breakdown torque factor
- dr.24
Selection speed detection
- dr.25
Line number incremental encoder 1
- dr.29
Track change channel 1
- dr.30
Line numer incremental encoder 2
- dr.34
Track change channel 2
- dr.35
Gearbox factor channel 1
- dr.36
Gearbox factor channel 2
- dr.37
Filter incremental encoder 1
- dr.38
Filter incremental encoder 2
- dr.43
Rotation direction initiator
- An.26 Interference filter analog optional input
- An.27 Zero point hysteresis analog optional input
- uF.8
DC-link compensation min. 10V
- do.1-4 Switching condition 1 to 4 value „36" and „37"
not available
- di.20
Value „2" not available
- In.15, In.16, In,19, In.21, In23
=2kΩ
i
=2kΩ
i
>56kΩ const.
B
©
Control Cards
KEB Antriebsteclnik, 1997
All Rights reserved

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents