KEB COMBIVERT F4-C Applications Manual page 180

Hide thumbs Also See for COMBIVERT F4-C:
Table of Contents

Advertisement

Special Functions
Setpoint Value and Direction of
Rotation (oP.0)
Motor Potentiometer/Target
(oP.31)
Used Parameters
R/W
PROG.
Param.
Adr.
ru.34
2022h
-
oP.0
2100h
oP.26
211Ah
-
oP.27
211Bh
-
oP.28
211Ch
-
oP.29
211Dh
-
oP.30
211Eh
oP.31
211Fh
di.3
2903h
:
:
di.10
290Ah
©
KEB Antriebstechnik, 1997
All Rights reserved
In order to adjust the setpoint value via the motor potentiometer oP.0 (set value source)
must be adjusted accordingly.
Apart from the setpoint value setting the motor potentiometer can be assigned to
further functions. For that the actual percentage (ru.34) is represented on a defined
parameter, the target parameter, and can change it. Possible target parameters are:
To prevent any dead travel in the motor potentiometer the maximum operating range
(oP.28) should be adjusted to the corresponding percentage.
ENTER
min
-
100,00
100,00
0
26
-
-
0
15
-
-
-100,00
100,00
-
-
-100,00
100,00
-
-
0
300,00 s
-
0
-
0
-
0
16
Name: Basis
KEB COMBIVERT F4-C
Functional Description
Rotation
oP.0
Keyboard/Bus
15
Terminal strip
16
±Motor potent.
17
oP.31
Motor potentiometer / Target
0
no target parameter
1
dr.35 gearbox factor channel 1 (62,5%)
2
dr.36 gearbox factor channel 2 (62,5%)
(max. parameter value at ...% attained)
Step
max
default
0,01
0
1
1
1
8
0,01
0,00
0,01
0,00
0,01s
131,00s
8
1
0
2
1
0
1
0
ANTRIEBSTECHNIK
ANTRIEBSTECHNIK
Set Value
Motor potent.
Motor potent.
Motor potent.
-
Value 15, 16 o. 17
-
-
-
-
-
-
Adjust value 7, 8 o. 10
Chapter
Date
Section
6
9
29.01.98
6
Page
15
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents