Operating and Appliance Displays
ru. 6 Setpoint frequency display
Adr.
2006h
Display of the current setpoint frequency. The display occurs as in ru.3. For control reasons the setpoint frequency is
also indicated, when control release or direction of rotation are not actuated. If no direction of rotation is adjusted, the
setpoint frequency for clockwise rotation (forward) is displayed.
With ud.10 the display can be changed to a resolution of 0,1 Hz.
ru. 7 Actual load
Adr.
2007h
Display of the actual load related to the rated current of the inverter. Only positive values are displayed, thus a
differentiation between motoric and generatoric operation is not possible.
ru. 8 Peak load
Adr.
2008h
ru.8 allows the detection of short-time peak loads during an operating cycle. For that the highest detected value of ru.7
is stored in ru.8. The peak value memory is cleared by pressing the keys UP or DOWN or by bus by writing any chosen
value to the address of ru.8. The disconnection of the inverter also results in a clearing of the memory.
ru.9
Apparent current
Adr.
2009h
Display of actual apparent curent. The maximum values depend on the size of the inverter.
ru.10 Active current
Adr.
200Ah
Display of the torque-forming active current (stator losses already deducted). Thus the display is nearly proportional to
the supplied torque. Precondition is the input of the motor data in dr.1...dr.5. The maximum values depend on the size
of the inverter.
©
KEB Antriebstechnik, 1999
All Rights reserved
!ud.11!
min
max
-409,58
409,58
min
max
0
200
min
max
0
200
min
max
0
unit-dependent
min
max
0
unit-dependent
Name: Basis
KEB COMBIVERT F4-C
Functional Description
ud.11
Hz
0,0125
%
1
%
1
A
0,1
A
0,1
Date
09.04.99
ANTRIEBSTECHNIK
default
-
default
-
default
-
default
-
default
-
Chapter
Section
Page
9
6
1
9
6