2.1.7
Unit Sizes 400V-Class (07-17)
Inverter Size
Output nominal power
Max. rated motor power
Output nominal current
Max. short-time current
OC-tripping current
Nominal input current
Housing size
Rated operating frequency
Max.operating frequency
Power loss at nominal operating
Stall current at 8kHz
Stall current at 16kHz
Max. heat sink temperatureT
OH
Max. permissible mains fuse (inert)
Line cross section
2)
Min. braking resistor
2)
Typ. braking resistor
Max. braking current
Tightening torque for terminals
3)
Mains voltage
Phases
Mains frequency
Output voltage
Output frequency
Shielded motor line length
Storage temperature
Operating temperature
Model / protective system
Relative humidity
Tested in accordance with...
Climatic category
1)
From housing size M fuses of Type Ferra Z 6,6 URD xxx must be used.
2)
This data is only valid for units with internal brake transistor (see „2.1.4 Type Code").
At mains voltage ≥460V multiply the nominal current with factor 0,86.
3)
4)
These units can be used with one or more braking modules. For more informations cantact KEB.
©
KEB Antriebstechnik, 1999
All Rights reserved
07
09
10
[kVA] 1,8
2,8
4
[kW] 0,8
1,5
2,2
[A] 2,6
4,1
5,8
[A] 4,6
7,4
10,4
[A] 5,7
9
12,7
[A] 2,8
4,5
6,4
D
D
D
D
[kHz]
4
4
4
12
[kHz]
4
4
4
12
[W] 45
60
80
130 115 180 135 240 200 240 260 260 290 360 310 490 360 470 700
[A]
-
-
-
6,4
[A]
-
-
-
-
[°C]
85
79
1)
[A]
10
10
[mm²]
1,5
1,5
[Ω]
160
160
[Ω]
390
270
[A]
5
[Nm]
0,5
[V]
[Hz]
[V]
[Hz]
[m] 50
50
100
[°C]
[°C]
Name: Basis
KEB COMBIVERT F4-C
12
13
14
6,6
8,3
11
4
5,5
7,5
9,5
12
16,5
17,1
21,6
18
30
20,9
26,4
22
36
10,5
13,2
18,1
D
E
D
E
G
E
4
16
2
16
8
4
16
4
16
16
-
9,5
-
12
19
17
-
9,5
-
12
12
-
85
73
79
73
90
73
20
20
25
2,5
2,5
4
82
50
82
50
39
50
150
100
82
10
15
10
15
21
15
1,2
0,5
305...500 +/-0 (400V Nominal voltage)
3
50 / 60 +/- 2
3 x 0...U Mains
see control board
100
100
100
-25...70 °C
-10...45 °C
IP20
max. 95% without condensation
EN 61800-3
3K3 in accordance with EN 50178
Summary
ANTRIEBSTECHNIK
15
16
17
23
11
15
24
33
25
36
49,5
30
43,2
59,4
26,5
36,5
G
E
G
H
G
H
16
4
8
16
8
16
16
12
16
16
16
16
19
-
19
25
22
33
12
-
8,5
15
9,7
20
90
73
90
90
35
50
6
10
39
39
22
25
22
56
39
21
21
37
30
37
1,2
0,5
1,2
2,5
1,2
1)
100
100
Date
Chapter
Section
2
1
09.04.99
17
29
18,5
2
42
63
75,6
46
G
H
R
4
8
16
16
16
16
-
30
42
-
14
30
90
79
63
16
25
22
9
28
30
37
88
2,5
100
Page
7
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents