Set Value and Ramp Adjustment
2. Direction of rotation via
terminal strip
3. Direction of rotation via
sign of set value
di.20 Functioning mode of
rotation setting
Picture 6.4.2.c
Principle of di.20 Bit2
Set value
Bit 2 = „0"
©
KEB Antriebstechnik, 1997
All Rights reserved
The direction of rotation can be activated by assigning terminal „F" (forward X1.10) or
„R" (reverse X1.11), If both terminals are assigned simultaneously then the direction
of rotation „forward" has priority.
Connection / activation of direction of rotation see Chapter 6.3 „Digital In- and Out-
puts" .
The direction of rotation can be defined by the adjusted set value signal. For analog
singals through adjustment of positive or negative voltages. For digital signals through
adjustment of positive (without sign) or negative values (negative sign in the display).
For the factory setting apply following rules:
Set value 0
Positive value
Negative value
With parameter di.20 the adjustment of direction of rotation can be adapted to special
applications.
di.20
Bit
dec. 2
1
0
0
0
1
0
0
2
0
1
3
0
1
4
1
0
5
1
0
6
1
1
7
1
1
Analog_internal
Name: Basis
KEB COMBIVERT F4-C
Functional Description
->
Rotation forward (F
->
Rotation forward
->
Rotation reverse
Bit 0: Behaviour of inputs X1.10 and X1.11
0:
Run/Stop
1:
Forward/Reverse
0
Bit 1: LS-behaviour at set value-dependent rotation
0
setting and set value 0
1
0:
no LS
0
1:
LS if Kl. X1.10/11=0 and oP.3=LS
1
0
Bit 2: Behaviour of negative set values at digital
1
rotation setting or adjustment via terminal strip
0
0:
Negative set values are set to 0
1
1:
Absolute-value generation of set value
Set value
Bit 2 = „1"
Date
28.01.98
ANTRIEBSTECHNIK
=0Hz)
set
Analog_internal
Chapter
Section
Page
7
6
4
7
6

Hide quick links: