9. Troubleshooting
Message
Right Front Cover is
open / Close Right Front
Cover
Right Int. Unit almost full
Routine Maint. Required
SCXXX-XX Power Off
On / Call Service if error
reoccurs
Set Tray
Size Mismatch
Tray to print or Stop to
reset
Temp. alert Please wait...
Top Cover open close it
to / restart machine /
Power Off On
Used Ink Collect Unit is
set / Replace Ink
Collector Unit
Used Ink Crtrdge /
Replace Ink Crtg
• If this does not eliminate the problem, contact your sales or service representative.
228
Causes
The right front cover is
open.
Internal unit is a service
replacement part.
Regular maintenance is
needed.
An error has occurred.
The cassette is not
loaded.
The cassette of the
specified size is not set.
The machine is too hot or
cold at start-up.
The top cover is open.
A used ink collector unit
was installed.
A used ink cartridge was
installed.
Solutions
Close the right front cover.
See page 230 "Cover Open".
For details about internal unit replacement,
contact your sales or service representative.
Clean both the Maintenance Unit and the
print head.
See page 133 "Clean Maint Unit" and
page 136 "Auto Head Maint.".
Turn the machine off and then on. If the
message reappears, contact your sales or
service representative.
Load the cassette on the cassette stand.
Change the print size. For details, see
page 87 "Selecting the Cassette Size and
Direction". To continue printing without size
mismatch, press the [Tray] key.
Wait until "Ready" appears on the display.
Close the top cover.
See page 230 "Cover Open".
Install a new ink collector unit.
See page 188 "Replacing an Ink Collector
Unit".
Replace the ink cartridge for the color
indicated by the
or
See page 182 "Replacing an Ink Cartridge".
icon.